At TXO, we excel in providing specialised repair and support services for the Alcatel-Lucent/Nokia 1660 SM. Our extensive inventory of refurbished parts and components allows us to efficiently manage refurbishment and repair for the entire Alcatel-Lucent/Nokia 1660 SM series. Our dedicated team is here to offer expert assistance and ensure the optimal functionality of your Alcatel-Lucent/Nokia 1660 SM systems. 


Availability and Shipping for the Alcatel-Lucent/Nokia 1660 SM 

We ensure prompt dispatch of most Alcatel-Lucent/Nokia1660 SM parts upon order receipt. International deliveries are typically completed within 3-5 days, while UK orders arrive within 1-3 days. For specific details about stock availability and delivery schedules tailored to your location, please contact us directly. 


About the Alcatel-Lucent/Nokia 1660 SM: a versatile solution for modern networks 

The Alcatel-Lucent/Nokia 1660 SM stands out as a top-tier multiservice provisioning platform (MSPP), designed to meet the diverse needs of contemporary telecommunications networks. Suitable for both metropolitan and regional applications, this unit is engineered for flexibility, reliability, and high performance. 

This powerful platform supports SDH cross-connect and CWDM add/drop functions, allowing for efficient transmission of extensive voice and data traffic over a single fibre. Its 10G capacity and support for carrier-class Layer 2 packet/cell switching, along with resilient packet ring protocols and integration with MPLS, GMPLS, and ATM, make it a comprehensive solution for various networking scenarios. Featuring Ethernet, Fast Ethernet, and Gigabit Ethernet interfaces, the Alcatel-Lucent/Nokia 1660 SM is ideal for new installations or enhancing existing network infrastructures. 

As an STM-64 optical multiservice node, the Alcatel 1660 SM is a reliable choice for both expanding existing systems and deploying new ones, ensuring robust performance and flexibility for a range of telecommunications applications. 


Component List: Part numbers from Alcatel-Lucent/Nokia 1660 SM eligible for repair. 

Part Number Description
3AL97001AA Alcatel 1660 SM Main Chassis
3AL97002AA Alcatel 1660 SM Power Supply Unit (PSU)
3AL97003AA Alcatel 1660 SM Fan Tray
3AL97004AA Alcatel 1660 SM Interface Module - SDH/STM-1
3AL97005AA Alcatel 1660 SM Interface Module - SDH/STM-4
3AL97006AA Alcatel 1660 SM Interface Module - Ethernet 10/100BASE-T
3AL97007AA Alcatel 1660 SM Interface Module - Gigabit Ethernet (GbE)
3AL97008AA Alcatel 1660 SM Interface Module – ATM
3AL97009AA Alcatel 1660 SM Interface Module – IP
3AL97010AA Alcatel 1660 SM L2-VPN Interface Module
3AL97011AA Alcatel 1660 SM Power Distribution Unit (PDU)
3AL97012AA Alcatel 1660 SM Network Management Card
3AL97013AA Alcatel 1660 SM Synchronisation Module
3AL97014AA Alcatel 1660 SM Protection Module

Repair Services for Alcatel-Lucent/Nokia 1660 SM 

At TXO, we specialise in addressing a comprehensive array of repair needs for the Alcatel-Lucent/Nokia 1660 SM. Our repair services encompass thorough diagnostics and meticulous repair of critical components such as interface modules, power supplies, and fan trays. Each part is subject to stringent testing and refurbishment processes to restore it to its original performance standards, ensuring that your network remains both robust and reliable. 

Our repair protocol includes detailed system inspections and proactive measures to address potential issues before they impact your operations. This includes firmware updates and performance assessments to ensure optimal functionality. By focusing on preventive maintenance and early issue detection, we help to extend the lifespan of your equipment and maintain its operational efficiency. 

TXO is committed to minimising downtime with our rapid response and advance replacement services. We understand the importance of maintaining continuous network operations, and our swift turnarounds are designed to keep your Alcatel-Lucent/Nokia 1660 SM system running smoothly. Our dedication to high-quality repairs and timely service guarantees that your network infrastructure remains stable and effective. 


Technical Specifications: Alcatel-Lucent/Nokia 1660 SM 

FeaturesSpecifications
Interfaces per board • 63 x 2 Mb/s: ISDN-PRA and retiming function
• 3 x 34/45 Mb/s switchable
• 4 x 140 Mb/s/STM-1 switchable
• 4 x STM-1: electrical, S-1.1, L-1.1, L-1.2
• 16 x STM-1 electrical/optical
• 4 x OC-3 with administrative unit (AU)3/ tributary unit (TU)3 conversion
• 4 x STM-4: S-4.1, L-4.1, L-4.2
• 1 x STM-16: I-16.1, S-16.1, L-16.1,L-16.2
• 1 x L-16.2 coloured optics DWDM
• 1 x L-16.2 coloured optics CWDM
• 1 x STM-64: very short reach (VSR)/I-64.1, S-64.2b S-64.2b
P1L1-2D2
• Integrated booster +10 dB/+15 dB/+17 dB
• 4 x any sublambda multiplexing function (4 channels in 2.5G
lambda): transparent Ethernet/FE, GE, STM-4, FC, ESCON,
FICON, FDDI, Dvideo
• Digital video broadcasting (DVB)ASI blade
• Up to 14 x Ethernet 10/100BASE-T per ISA blade
• Up to 8 x Ethernet 10/100BASE-FX per ISA blade
• Up to 4 x GE BASE-SX/LX per ISA blade
Connectivity • 384 x 384 (HO)/256 x 256 (LO) STM-1 equivalent fully nonblocking SDH fabric in all configurations
• Unidirectional, bidirectional, drop-and-continue multicast,
broadcast SDH connections
• Line and virtual container (VC)loopbacks
• Virtual concatenation (VCAT)and contiguous concatenation
• 1- or 2-channel CWDM optical add/drop multiplexer (OADM)
function
• 8-channel CWDM MUX/DEMUX function
• Embedded ATM star, ring, and mesh topologies
• Embedded Ethernet/MPLS star, ring, and mesh topologies
• Embedded Ethernet/multiple-ring topologies
Equipment protection • Matrix, control, and synchronisation EPS 1 + 1
• ISA-ATM switch EPS 1 + 1
• ISA- Ethernet switch (ES)16 EPS 1 + 1
• 63 x 2 Mb/s EPS N + 1, maximum N = 6
• 3 x 34/45 Mb/s EPS N + 1, maximum N = 15
• 4 x STM-1e EPS N + 1, maximum N = 15
• 16 x STM-1e EPS N + 1, maximum N = 15
Network protection Transport
• Linear single/dual-ended 1 + 1 APS at STM-1/4/16/64
• Linear dual-ended N + 1 APS at STM-1/4/16
• SNCP/I, SNCP/N
• SNCP drop-and-continue plus insertion
• Multiplex Section-Protection Ring (MSPRING) drop-and-continue plus insertion
• 2 x 2 fiber MSPRING at STM-16/64
• Collapsed single-node ring interconnection
• Collapsed dual-node ring interconnection
Packet
• Dual attach: packet-ring interconnection
Monitoring • Performance monitoring according to G.784, G.826, G.821
• Path overhead monitoring (POM) on all VCs
• Supervisory unequipped trail (SUT)
• Tandem connection monitoring (TCM)
• Ethernet performance monitoring counters
¬ Port/aggregate/flow
¬ Incoming/outgoing
Synchronisation • Internal oscillator ±4.6 ppm
• Holdover drift ±0.37 ppm per day
• External sources: STM-n/2 Mb/s ports, 1 external 2 MHz/2 Mb/s output
• Priority and quality SSM synchronisation algorithm
Data blades-ISA ISA-ATM
• 600 Mb/s and 1.2 Gb/s cell switch with optional STM-1 access on board
• Equipment protection 1 + 1
• VPC/VCC switch/cross-connect
• Hard/soft PVC connections for PNNI
• Point-to-point/multipoint from E1 up to VC4-4c payloads
• Up to 252 ATM logical ports
• IMA support: maximum126 groups/32 links
• Policing, shaping, congestion management
• CBR, UBR, UBR+, rt-VBR/nrt-VPR, GFR ATM traffic contracts
• ATM operations, administration, and maintenance (OAM)

ISA-ES1
• 1 Gb/s throughput
• 155 Mb/s back-panel capacity
• 8 x Ethernet 10/100BASE-T/FX
• GFP-F/LAPS, VCAT, LCAS
• LACP
• VC-12/VC-3/VC-4 terminations
• VCGroups: maximum 8 at 50/2/1
• Classification/forwarding
¬ Per port
¬ MAC DA 802.3
¬ C-VLAN/S-VLAN
¬ 802.1p
¬ DSCP/TOS
¬ Ethertype
• Ethernet multicast: IGMP
• Ethernet OAM, CFM
• Q-in-Q: 802.1Q/ad
• QoS 802.1p
• CoS
¬ Guaranteed
¬ Regulated
¬ Best effort
• Congestion avoidance
• STP/RSTP/MSTP/PVSTP: 802.1d/w/s
• Ethernet performance counters
¬ Per port/aggregate/flow
¬ Incoming/outgoing
¬ Unicast
¬ Multicast
¬ Broadcast
• E-line, E-LAN, Ethernet aggregation services in accordance with MEF

ISA-ES4
• 2.5 Gb/s throughput
• 622 Mb/s back-panel capacity
• 1 x GE using SFP, 8 x Ethernet 10/100BASE-T
• GFP-F/LAPS, VCAT, LCAS
• LACP
• VC-12/VC-3/VC-4 terminations
• VCGroups: maximum 16 at 63/12/4
• Classification/forwarding
¬ Per port
¬ MAC DA 802.3
¬ C-VLAN/S-VLAN
¬ 802.1p
¬ DSCP/TOS
¬ Ethertype
• Ethernet multicast: IGMP
• Ethernet OAM CFM
• Q-in-Q: 802.1Q/ad
• QoS 802.1p
• CoS
¬ Guaranteed
¬ Regulated
¬ Best effort
• STP/RSTP/MSTP/PVSTP: 802.1d/w/s
• Congestion avoidance
• Ethernet performance counters
¬ Per port/aggregate/flow
¬ Incoming/outgoing
¬ Unicast
¬ Multicast
¬ Broadcast
• E-line, E-LAN, Ethernet aggregation services in accordance with MEF

ISA-ES16
• 4.5 Gb/s throughput
• 2.5 Gb/s back-panel capacity
• 4 x GE (SFP), 14 x Ethernet 10/100BASE-T, 7 x 10/100BASE-FX
• GFP-F/LAPS, VCAT, LCAS
• LACP
• VC-12/VC-3/VC-4 terminations
• VCGroups: maximum 64 at 63/12/16
• Classification/forwarding
¬ Per port
¬ MAC DA 802.3
¬ C-VLAN/S-VLAN
¬ 802.1p
¬ DSCP/TOS
¬ Ethertype
¬ MPLS label switching (pseudowire/tunnel)
¬ MPLS exp bits
• Ethernet and MPLS multicast, IGMP
• Martini encapsulation
• Q-in-Q: 802.1Q/ad
• QoS 802.1p, MPLS
• CoS
¬ Guaranteed
¬ Regulated
¬ Best effort up to eight CoS
• Policing dual rate token bucket, metering, marking, CIR/CBS, EIR/ EBS, dropping (OOP)
• Scheduling HOL, weighted-deficit round robin
• Congestion avoidance weighted random early detection (WRED) per queue
• STP/RSTP/MSTP/PVSTP: 802.1d/w/s
• Ethernet and MPLS performance counters
¬ Per port/aggregate/flow
¬ Incoming/outgoing
¬ Unicast
¬ Multicast
¬ Broadcast
• Ethernet OAM CFM
• E-line/ VLL, E-LAN/VPLS, Ethernet aggregation services in accordance with MEF

DVB-ASI Unidirectional transparent transport
• CBR MPEG-x transport stream (TS)
¬ Single program TS (SPTS)
¬ Multiple program TS (MPTS)
• TS rate: 1.5 Mb/s to maximum 100 Mb/s with C-12 or C-3 granularity
Power • Station battery: -48 V/-60 V DC
• Power consumption: 250 W (typical)
Dimensions Rack size
• Height: 2.2 m
• Width: 600 mm
• Depth: 300 mm

Subrack size
• Height: 650 mm
• Width: 482 mm
• Depth: 250 mm
compliance Environmental
• Operating conditions: ETS 300 019, class 3.2
• Storage conditions: ETS 300 019,class 1.2
• Transportation conditions: ETS 300 019, class 2.2
• ESD/EMC: ETS 300 386, “Telecommunications Center”

Mechanical
• Mechanical compatibility: ETSI ETS/E3, S9

Operational
• Alcatel-Lucent 1350 Optical Management System (OMS)
• CMISE craft terminal through TIA/EIA-232 at 38.4 kb/s
• Network management access through QB3 G.773 interface or Qecc G.784
• Protocol stack and information model: according to ITU-T G.774 and ETSI rec. ISO-OSI; IP and SNMP tunneling over OSI
• Local and remote software download
• Remote inventory
• Housekeeping: six inputs plus two outputs
• Auxiliary channels

¬ EOW
¬ 4 x 64 kb/s G.703
¬ 4 x TIA/EIA-232
¬ 4 x V.11
¬ 2 x 2 Mb/s G.703
Standards • In compliance with all the latestrelevant standards of ITU-T
¬ G.7041
¬ G.7042
¬ G.707
• ETSI
• ATM Forum
• IETF
• IEEE
• MEF 9 and 14 certified

For full details of the Alcatel-Lucent/Nokia 1660 SM a high-capacity optical transport platform, please view the data sheet here.


We’re here to help: reach out to TXO for Alcatel 1660 SM support 

For all your Alcatel-Lucent/Nokia 1660 SM needs, TXO is dedicated to delivering exceptional support and service. Our skilled team is ready to assist with a comprehensive range of services, including repairs, configuration, and technical enquiries related to the Alcatel-Lucent/Nokia 1660 SM. Whether you require expert guidance on troubleshooting, routine maintenance, or optimising the performance of your Alcatel-Lucent/Nokia 1660 SM system, our knowledgeable professionals are here to ensure your network runs smoothly. 

We are committed to providing prompt and effective solutions to minimise downtime and sustain the stability of your network. Our support services are designed to enhance the reliability and efficiency of your Alcatel-Lucent/Nokia 1660 SM, ensuring that it continues to meet your operational requirements. For further assistance or to learn more about how TXO can support your Alcatel-Lucent/Nokia 1660 SM system, please contact us today. 

Please note that TXO operates independently and is not officially affiliated with Alcatel-Lucent/Nokia. We are dedicated to offering dependable and professional support tailored to your specific needs, ensuring your Alcatel-Lucent/Nokia 1660 SM equipment performs at its best.